<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Activity for AdvancedHMI</title><link>https://sourceforge.net/p/advancedhmi/activity/</link><description>Recent activity for AdvancedHMI</description><language>en</language><lastBuildDate>Wed, 29 Apr 2020 23:59:28 -0000</lastBuildDate><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ae11fec9d2/?limit=25#87d8</link><description>You have to be a member of the AdvancedHMI forum to see the beta testing forum</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 29 Apr 2020 23:59:28 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ae11fec9d2/?limit=25#87d8</guid></item><item><title>aris sugi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ae11fec9d2/?limit=25#7d1a</link><description>hi, I'm using advancedhmi version 3.99x now, it is a great hmi program, i can learn so many thing with this program. anyone know is there any update ? i have read in the forum there is beta version can anyone send me download link of the 3.99y beta ? i have been go to the advancedhmi forum but did'nt find the download link thank you aris</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">aris sugi</dc:creator><pubDate>Wed, 29 Apr 2020 23:42:32 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ae11fec9d2/?limit=25#7d1a</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#4d83</link><description>To the best of my knowledge the first SLC 5/05 processors came out before Ethernet/IP was developed. If you dissect the ABEthernet packet, you can see how it was the start and evolved into what is now Ethernet/IP. I can't imagine anyway a ABEthernet processor could hold a CIP (Ethernet/IP) connection, especially considering it is a different TCP/IP port.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 17:54:55 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#4d83</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#bd8f</link><description>I asked the question and our maintenance team did change out the processor. They say it was 3 weeks ago and that it was working for at least a week since it was changed out up until the power outage this Monday. We're also requisitioning for a new processor and this replacement should fix our issue. Perhaps the power outage reset something that was allowing the CIP connection to be maintained somehow. Thanks, MC</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 15:26:01 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#bd8f</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#f145</link><description>Though I don't disagree that it sounds like that, it seems very inplausable; I will ask the question though. The Ethernet/IP driver does not connect to it. Interestingly, a computer that utilizes Ethernet/IP driver exclusively was showing the PLC but with an X implying that it had seen it before but no longer sees it and it would not reconnect to it using that driver but it would connect to it using the Ethernet Device driver (where you type in the specific IP address). Do you think it's possible...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 14:59:47 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#f145</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#0363</link><description>Port 2222 is an older protocol, not Ethernet/IP. The early versions of the SLC 5/05 did not support Ethernet/IP AdvancedHMI does not support that older protocol. In RSLinx try using the Ethernet/IP driver (not the Ethernet driver) to see if it works. I am going to take a wild guess and say that if it worked before, then someone swapped out your SLC processor with an older processor.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 14:48:04 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#0363</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#39c5</link><description>The wireshark capture here is interesting i guess. It's filtered again for only that PLC. I have RSLinx running and we can see that every RSLinx communication (port 62304 to 2222) is successful and every BasicLabel communication (Dynamic port to 44818) is not successful. Perhaps this is a hint?</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 14:35:27 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#39c5</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#e506</link><description>The original wireshark image was showing all traffic that involved the 10.60.48.215 IPAddress, the PLC. I opened up the AdvancedHMIv35 solution with a single BasicLabel (the one that's currently saying cannot connect and No response from Forward Open) and ran wireshark filtering for only the CIP protocol. There is mention of two IP addresses that are not mine; I'm not entirely sure what they are but they continue to occur even when the BasicLabel app is not running so I assume they're unrelated....</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 14:28:08 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#e506</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#3b31</link><description>One quick thing to try... In the driver properties, reduce the CIPConnectionSize to 200. Some older PLCs can't handle the 508</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 14:17:50 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#3b31</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#dcc5</link><description>The Wireshark screen capture isn't enough for me to diagnose the problem. You can try adding "cip" in the filter to see only the traffic of it talking to the PLC</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 14:15:00 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#dcc5</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#2a5e</link><description>I switched to the drivers to what i downloaded yesterday. The parent solution was labeled v35 so I think that's the one you are referring to. The version numbers actually decreased so maybe I've missed something: AdvancedHMIControls 3.9.9.24 AdvancedHMIDrivers 3.9.9.24 MfgControl.AdvancedHMI.Controls 1.0.0.0 MfgControl.AdvancedHMI.Drivers 3.99.19.2 Never the less, the issue persists. Also, F8:8 isn't necessarily the issue. I have not found success in reading anything from the PLC though, again, the...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 14:10:08 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#2a5e</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#a39a</link><description>Ok. That's 3.99y Beta 10. The beta is now up to 35. You would need to go to the AdvancedHMI forum to download the latest beta. I can test the F8:8, but it will take me a couple hours to get to everything to set it up.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 14:00:12 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#a39a</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#b5b4</link><description>The test in the image above is using the following: AdvancedHMIControls 3.9.9.2510 AdvancedHMIDrivers 3.9.9.2510 MfgControl.AdvancedHMI.Controls 1.0.0.0 (says Runtime Version v4.0.30319 if that's more helpful) MfgControl.AdvancedHMI.Drivers 3.99.19.7 I downloaded the latest drivers from the website in order to do the test that the wireshark data is based on. The BasicLabel is on the black form screen that was included in the solution downloaded. Thanks, MC</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 13:57:37 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#b5b4</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#b9e5</link><description>What version of AdvancedHMI are you using? If not using at least 3.99x, I would recommend a quick test witrh that version.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 15 Apr 2020 13:52:14 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#b9e5</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#c8f0</link><description>Archie, I wanted to provide one other detail in the attachment below. As you can see, when a direct read is attempted on one of the SLC 5/05 PLCs, there is no issue but yet the other throws a NullReference exception although for each, you can see valid data in both of the F8:8 PLC addresses using RSLinx. Thanks, MC</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 13:19:33 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#c8f0</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#c587</link><description>Archie, Thanks for the quick reply. I have used wireshark to observe that there does appear to be an issue but I apologize for I am not network savvy enough to have an "ah ha!" moment looking at it. The attachment shows a filtered log of 1 BasicLabel attempting to update itself and presenting the messages mentioned in the above message. The real head scratcher for my team and I is that RSLinx allows us to view data but our AdvancedHMI drivers are not having the same success which leads us to believe...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Wed, 15 Apr 2020 12:40:56 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#c587</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#a23a</link><description>No settings that I am aware of could change. I would do a WireShark to look at the traffic</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Tue, 14 Apr 2020 23:08:59 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#a23a</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#74cd</link><description>I am having trouble communicating with a SLC-5/05 PLC. There was a power outage and although we are having no trouble connecting to the PLC using RSLinx, our HMIs built with AdvancedHMI drivers are getting no results. The basic labels state: Could not connect to xx.xx.xx.xx, port 44818. Timed out No response from Forward Open When doing a direct .Read, the response is: Read Failed - No Response We are able to view the values on the PLC through RSLinx data monitor and log into it using RSLogix 500....</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Tue, 14 Apr 2020 20:36:00 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/c04a28b108/?limit=25#74cd</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#20ac</link><description>Thanks for the feedback. Your suggestion was exactly what the issue was.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Tue, 14 Apr 2020 20:29:24 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#20ac</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#8ac9</link><description>Route paths must always be in groups of pairs. So you do need the ,0 on the end of what you have. My guess is that your L1 processor does not support a 508 CIP connection size. Try reducing that to 100</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Tue, 25 Feb 2020 22:16:31 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#8ac9</guid></item><item><title>Joseph Cauley posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#9301</link><description>I followed the ifnormation described below as best as I could but have still been unsuccessful at getting any reads from a PLC begin a controlnet module. https://advancedhmi.com/documentation/index.php?title=Routing_Paths EthernetIPforCLX plctest = new EthernetIPforCLX(); plctest.IPAddress = "10.60.48.211"; plctest.RoutePath = "1,0,2,3,1"; plctest.ProcessorSlot = 0; CLXTag[] tags = plctest.GetTagList(); I've tried this with a ",0" at the end of the path to signify the processer location as well in...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Joseph Cauley</dc:creator><pubDate>Tue, 25 Feb 2020 15:32:29 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/b3fca1cec0/?limit=25#9301</guid></item><item><title>m s posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1cf109ee92/?limit=25#c640</link><description>Hi this is Mike i am doing a very first try at advanced HMI on a 5/04 i think i do not have all params sut up correct on simple push button i am set up on one of the old blue 4 slot SLC trainers my pgm works on trainer push button light goes on push other button light goes off . when i have the HMI on screen i push button light and on screen comes on (cool) and the button on screen reacts i push other button light goes off and other button on screen reacts but when t try and click buttons on screen...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">m s</dc:creator><pubDate>Tue, 28 Jan 2020 23:10:17 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1cf109ee92/?limit=25#c640</guid></item><item><title>Michael Freed posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/a727b370a4/?limit=25#8b39</link><description>Problem solved. You need to install the correct "Workload" in Viual Studio. I was missing Universal Windows Platform development.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Michael Freed</dc:creator><pubDate>Tue, 10 Dec 2019 02:02:47 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/a727b370a4/?limit=25#8b39</guid></item><item><title>Michael Freed posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/a727b370a4/?limit=25#9fc3</link><description>Hello, I admit I am rather new to VS 2019 but I am finding my way. So this might be a very simple question. How do you make a new Form? So far the project opens and defaults to MainForm.vb and Page2.vb. I havn't been able to make new forms. Right clicking on the AdvancedHMI Project allows me to: Add-&gt;Windows Form-&gt;Add New Item - AdvancedHMI window. In the Add New Item - Advanced HMI window there is no option for a Form Item. I suspect that there is some setting somewhere that I need to enable, but...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Michael Freed</dc:creator><pubDate>Mon, 09 Dec 2019 16:47:40 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/a727b370a4/?limit=25#9fc3</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/8c2fa2b4/?limit=25#bab3</link><description>DF1Comm is from a very old version. Go to the AdvancedHMI web site and get the latest version</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Tue, 03 Sep 2019 22:05:01 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/8c2fa2b4/?limit=25#bab3</guid></item><item><title>Hasala Senevirathne posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/8c2fa2b4/?limit=25#0898</link><description>There is a issue with timer's tag mapping . If you read T4:0.ACC it actually reads the .PRE- preset value. But writing to the .PRE works normally. eg: label1.text = DF1Comm1.ReadAny("T4:0.ACC") // This actually reads T4:0.PRE</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Hasala Senevirathne</dc:creator><pubDate>Tue, 03 Sep 2019 21:35:13 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/8c2fa2b4/?limit=25#0898</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMI.txt</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMI.txt/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Tue, 26 Feb 2019 22:27:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMI.txt/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SFdepart.txt</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SFdepart.txt/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Tue, 26 Feb 2019 22:26:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SFdepart.txt/download</guid></item><item><title>Bui Thanh Trung posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ffb7ec57b1/?limit=25#f940</link><description>Hi, Do any one have exp/example code to do Subscribe with 2D array using EthernetCLX Driver? Thank you so much!</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Bui Thanh Trung</dc:creator><pubDate>Mon, 18 Feb 2019 06:22:00 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ffb7ec57b1/?limit=25#f940</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/SaveDataTableAndRestoreCLX.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/SaveDataTableAndRestoreCLX.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 22 Oct 2018 19:20:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/SaveDataTableAndRestoreCLX.zip/download</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#0a5e</link><description>Hello I'need a "ejector" symbol for my ihm where I'can buy it ??</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Mon, 08 Oct 2018 13:06:10 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#0a5e</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#b5cc</link><description>Ok I'look this thanks you very much</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Thu, 04 Oct 2018 06:34:17 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#b5cc</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#3ed4/c561</link><description>Dd you follow the Quick Start guide that is included with the project? Or go to the AdvancedHMI web site and get it from the link on the main page.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 03 Oct 2018 10:58:48 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#3ed4/c561</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#3ed4</link><description>if you just have a sample code with gauge and button for exemple I think I will succeed in deceiving</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Wed, 03 Oct 2018 09:30:44 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#3ed4</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#adde</link><description>Yes, and I want to devellop in C#</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Wed, 03 Oct 2018 09:29:13 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#adde</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#e6fe</link><description>Community Edition?</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 03 Oct 2018 09:02:27 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#e6fe</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#9463</link><description>I am using Visual studio 2017</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Wed, 03 Oct 2018 07:28:02 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#9463</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#a6e8</link><description>AdvancedHMI does not require activation. Is it Visual Studio you are trying to activate? What version of Visual Studio are you using?</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Sun, 30 Sep 2018 12:38:51 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#a6e8</guid></item><item><title>Heinzou posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#1f70</link><description>Hello I start in the supervision and I would like to activate advancehmi on visual studio but I can not reach you can tell me the procedure to follow thank you sorry for my english I'm french and I try to make myself understood lol</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Heinzou</dc:creator><pubDate>Sun, 30 Sep 2018 11:32:46 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/54c36ba141/?limit=25#1f70</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/bc95c77d/?limit=25#10a1</link><description>Set the ComComponent property to point to your driver instance</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Sat, 15 Sep 2018 07:13:00 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/bc95c77d/?limit=25#10a1</guid></item><item><title>Eduardo Calles posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/55f0a46f/?limit=25#c499</link><description>Hello I am trying to connect with Kepware/KEPServerEX without sucess, First of all, I have successfullly installed Kepware on a Virtual Machine and connected to an Omron PLC. I grabbed the driver " opcDaCom1" and placed it on my Form1 project on Visual Studio C# project. On the following "opcDaCom1" properties , I typed what's between the following quotation marks: OPCServer = "Kepware.KEPServerEX.V6" OPCServerPath = "opc.tcp://172.19.32.50:49320" Next, I used a BasicIndicator and typed for the PLCAddressSelectColor2...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Eduardo Calles</dc:creator><pubDate>Sat, 15 Sep 2018 07:01:52 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/55f0a46f/?limit=25#c499</guid></item><item><title>Eduardo Calles modified a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ac1d2901/?limit=25#b6af</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Eduardo Calles</dc:creator><pubDate>Sat, 15 Sep 2018 06:20:10 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ac1d2901/?limit=25#b6af</guid></item><item><title>Eduardo Calles posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ac1d2901/?limit=25#b6af</link><description>Hello I just grab the driver "omronEthernetFINSCom1" and place it on my Form1 project on Visual Studio C# project. I typed my address of my PLC on the IP address, But, I am not so sure what is the format of my tag, For example on the CX-Programmer, my tag address is 3.13, so I just type 3.13 for my PLCAddressSelectColor2 for my BasicIndicator properties, but this is not working. When I play the application, my indicator doesn't show the correct state, but it shows a message for few seconds saying...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Eduardo Calles</dc:creator><pubDate>Sat, 15 Sep 2018 06:18:31 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/ac1d2901/?limit=25#b6af</guid></item><item><title>Eduardo Calles posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/bc95c77d/?limit=25#a795</link><description>Hello I just grab the driver "omronEthernetFINSCom1" and place it on my Form1 project on Visual Studio C# project. I typed my address of my PLC on the IP address, But, I am not so sure what is the format of my tag, For example on the CX-Programmer, my tag address is 3.13, so I just type 3.13 for my PLCAddressSelectColor2 for my BasicIndicator properties, but this is not working. When I play the application, my indicator doesn't show the correct state, but it shows a message for few seconds saying...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Eduardo Calles</dc:creator><pubDate>Sat, 15 Sep 2018 06:11:59 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/bc95c77d/?limit=25#a795</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/LargePressHMIonPanelPC.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/LargePressHMIonPanelPC.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Fri, 07 Sep 2018 21:02:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/LargePressHMIonPanelPC.zip/download</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/3fee67a6/?limit=25#4360</link><description>You may want to post on the official AdvancedHMI forum. It has much more users watching it. For the MessageDisplayByBit, you set the following properties: PLCAddressValues (e.g. N7:0) PLCElementBitWidth (e.g. 16) PLCNumberOfElements (e.g. 2 for 2 words of bits) You then go into the Messages property and define each message and indicate its corresponding bit</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Thu, 31 May 2018 00:01:11 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/3fee67a6/?limit=25#4360</guid></item><item><title>Jeff K posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/3fee67a6/?limit=25#8a99</link><description>I am new to HMI development. I am using Advanced HMI with RS Logix Micro. I would like to display text (representing alarms) when a specific bit is set. I have found some discussions on the subject but they are just a little advanced for me. I have tried use MessageDisplayByBit and I am missing some step in how to use it. Is there step by step insturctions that I can access? Thank you.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Jeff K</dc:creator><pubDate>Wed, 30 May 2018 19:04:38 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/3fee67a6/?limit=25#8a99</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1c702e6a/?limit=25#c437</link><description>Please post questions on the forum at the AdvancedHMI web site. It is where the experts monitor ona regular basis</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Wed, 16 May 2018 15:06:15 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1c702e6a/?limit=25#c437</guid></item><item><title>Henny posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1c702e6a/?limit=25#877c</link><description>Please could you provide me information for communication by Modbus TCP. To communicate with a WAGO PLC (Codesys V2.3)</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Henny</dc:creator><pubDate>Wed, 16 May 2018 14:52:00 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/1c702e6a/?limit=25#877c</guid></item><item><title>RODYan00 modified a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/a2bce815/?limit=25#1ee8</link><description>HI I did so chart chart is at 100 points How Can I solve this problem? thanks best regard Private Sub Timer1_Tick(sender As System.Object, e As System.EventArgs) Handles Timer1.Tick Dim Value As Integer '* Add</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">RODYan00</dc:creator><pubDate>Tue, 08 May 2018 09:24:52 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/a2bce815/?limit=25#1ee8</guid></item><item><title>RODYan00 posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/a2bce815/?limit=25#1ee8</link><description>HI I did so chart chart is at 100 points Private Sub Timer1_Tick(sender As System.Object, e As System.EventArgs) Handles Timer1.Tick Dim Value As Integer Try Value = ModbusRTUCom1.Read("41914", 1)(0) Catch ex As Exception Exit Sub End Try '* Add the next point to the chart ChartBySampling1.Series(0).Points.Add(Value) '* Do not let more than 100 point be on the chart If ChartBySampling1.Series.Count &gt; 100 Then ChartBySampling1.Series(0).Points.RemoveAt(0) End If End Sub</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">RODYan00</dc:creator><pubDate>Tue, 08 May 2018 08:59:02 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/a2bce815/?limit=25#1ee8</guid></item><item><title>Dhananjay Joshi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#de40</link><description>Ok, I understand, I saw Timings on forum page :). Counters and Timers go to oveflow Exception after subscription. while Booleans go to next Tag instead of Bit (B3:1, B3:2 instead of B3:1/0, B3:1/1). I'll work with forum then, Thanks.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Dhananjay Joshi</dc:creator><pubDate>Fri, 04 May 2018 11:54:32 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#de40</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#c419</link><description>The one thing you could try is to add a BasicLabel to the form and set PLCAddressValue to an addres that you say is not working, then run the application. All of the visual controls use the subscription mechanism, so it will prove out that it works or give an error to indicate the problem.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Fri, 04 May 2018 11:23:22 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#c419</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#6d46</link><description>It is still early here in North America so it may be a few hours before anyone sees the post. I am unable to check into it today because I will be giving a training class all day.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Fri, 04 May 2018 11:18:03 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#6d46</guid></item><item><title>Dhananjay Joshi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#3644</link><description>Hi Archie, Can you may be just ping some expert to respond on Forum where I have posted my question again. Please. I am on a clock...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Dhananjay Joshi</dc:creator><pubDate>Fri, 04 May 2018 11:07:06 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#3644</guid></item><item><title>Dhananjay Joshi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#db11</link><description>I followed this but does not work with Timers, Booleans or Counters. Any way I'll raise it in forum.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Dhananjay Joshi</dc:creator><pubDate>Fri, 04 May 2018 10:50:28 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#db11</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#5314</link><description>This could provide your answer, but the expert on the SLC/Micro frequents the forum. https://advancedhmi.com/documentation/index.php?title=Subscribing_to_PLC_data_via_code</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Fri, 04 May 2018 10:48:30 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#5314</guid></item><item><title>Dhananjay Joshi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#4bef</link><description>Hi Archie, I just need 2 Lines of code fore referencing to correct my logic. I need correct var Timers = Connection.Subscribe("Timertag", 50,100ms, Subscribedevent); var Counters= Connection.Subscribe("CounterTag", 50,100ms, Subscribedevent); var BooleanBits = Connection.Subscribe("BooleanBitTag(eg. B3:0/1)", 50,100ms, Subscribedevent); If you can give me that My problems will be fixed. Nothing more to discuss. Is it Still necessary to go to the forum? Greatwork BTW with Advanced HMI!</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Dhananjay Joshi</dc:creator><pubDate>Fri, 04 May 2018 10:40:44 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#4bef</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#84aa</link><description>If you post this on the official forum, you will get more responses: https://www.advancedhmi.com/forum/index.php</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Fri, 04 May 2018 10:28:39 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#84aa</guid></item><item><title>Dhananjay Joshi posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#172d</link><description>I am using AdvancedHMIv399x. I am not using any UI Controls, I am just using EthernetIPforSLCMicroCom.Read and Write. Recently I came across the Subscribe Event where PLC Polls Data after a Declare Time Interval. This will save me a Lot of Time for updating Values from PLC as 1by1 fetching Tags takes 10 ms (Specified on some other discussion). I can Fetch all Real bits normally with subscription but unable to work with Boolean Tags like B3:10/0-1-2-3 etc. and Timer valueslike T4:9.PRE, ACC, EN,DN...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Dhananjay Joshi</dc:creator><pubDate>Fri, 04 May 2018 10:10:32 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/7ef9f4f9/?limit=25#172d</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMIV399xPatched3.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIV399xPatched3.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Sat, 09 Dec 2017 15:56:01 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIV399xPatched3.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399xPatched2.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399xPatched2.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Fri, 08 Dec 2017 01:37:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399xPatched2.zip/download</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/373df866/?limit=25#ea3b</link><description>Are you trying to write more than 1 elements? That error typically comes from writing beyond the length of the data file. You also may want to post your question on the AdvancedHMI forum where you will get more responses.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Mon, 20 Nov 2017 16:18:48 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/373df866/?limit=25#ea3b</guid></item><item><title>Aravind Hari posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/373df866/?limit=25#daa5</link><description>I am trying to write a value to a tag address in Micrologix 1400 PLC through c# using MfgControl.AdvancedHMI.Drivers.dll. while writing the following error is thrown: Illegal Command or Format, Address may not exist or not enough elements in data file, StackTrace- at AdvancedHMIDrivers.AllenBradleyPCCC.WriteRawData(PCCCAddress PAddressO, Int32 numberOfBytes, Byte[] dataToWrite) at AdvancedHMIDrivers.AllenBradleyPCCC.WriteData(String startAddress, Int32 numberOfElements, Int32[] dataToWrite) at AdvancedHMIDrivers.AllenBradleyPCCC.WriteData(String...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Aravind Hari</dc:creator><pubDate>Mon, 20 Nov 2017 11:36:54 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/373df866/?limit=25#daa5</guid></item><item><title>Ronald Pennings posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#c286</link><description>Should I be using a null modem cable or a straight through cable</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Ronald Pennings</dc:creator><pubDate>Sun, 05 Nov 2017 23:31:11 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#c286</guid></item><item><title>Ronald Pennings posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#fd5d/e8fb</link><description>Hi and thanks for that, you have built the same project as i am trying to! except yours works! I must have a slightly different version of hmi as it will only let me have a poll rate override value of 500bits??? any suggestions?</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Ronald Pennings</dc:creator><pubDate>Sat, 04 Nov 2017 23:05:43 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#fd5d/e8fb</guid></item><item><title>cjawood posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#fd5d</link><description>.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">cjawood</dc:creator><pubDate>Sat, 04 Nov 2017 19:57:22 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#fd5d</guid></item><item><title>cjawood posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#9841</link><description>.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">cjawood</dc:creator><pubDate>Sat, 04 Nov 2017 19:54:27 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/5829e640/?limit=25#9841</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399xPatched.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399xPatched.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Thu, 28 Sep 2017 19:11:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399xPatched.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudioR1.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudioR1.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Thu, 07 Sep 2017 01:28:05 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudioR1.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudio.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudio.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Tue, 05 Sep 2017 00:08:01 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/DesignerFormInVisualStudio.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/GlobalsExample.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/GlobalsExample.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 04 Sep 2017 23:37:01 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/GlobalsExample.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/SampleProjects/KeepingRecordsfromCLXToExcelV399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/KeepingRecordsfromCLXToExcelV399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Fri, 25 Aug 2017 13:30:04 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/KeepingRecordsfromCLXToExcelV399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch8V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch8V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Thu, 24 Aug 2017 02:26:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch8V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch7V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch7V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Wed, 23 Aug 2017 16:23:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch7V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/AdvancedHMIDriversV399xPatch5.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/AdvancedHMIDriversV399xPatch5.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Wed, 23 Aug 2017 11:17:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/AdvancedHMIDriversV399xPatch5.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch5V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch5V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Wed, 23 Aug 2017 00:57:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch5V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 14 Aug 2017 19:23:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Sun, 13 Aug 2017 01:16:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch2V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch2V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Sat, 12 Aug 2017 19:57:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch2V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Wed, 09 Aug 2017 08:09:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399xPatch1.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399xPatch1.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Fri, 21 Jul 2017 02:04:04 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399xPatch1.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 17 Jul 2017 13:50:48 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399x.zip/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/Advanced HMI V3.99x</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Advanced%2520HMI%2520V3.99x/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 17 Jul 2017 13:41:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Advanced%20HMI%20V3.99x/download</guid></item><item><title>AdvancedHMI released /advancedhmi/3.5/AdvancedHMIv399x.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399x.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">AdvancedHMI</dc:creator><pubDate>Mon, 17 Jul 2017 13:40:18 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/AdvancedHMIv399x.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399w.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399w.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Tue, 16 May 2017 21:59:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch4V399w.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/SampleProjects/AdvancedHMIv35MsgByValueColorDemo.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/AdvancedHMIv35MsgByValueColorDemo.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Sat, 13 May 2017 00:27:11 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/AdvancedHMIv35MsgByValueColorDemo.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399w.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399w.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Tue, 25 Apr 2017 19:43:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch3V399w.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/SampleProjects/UserControlTest.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/UserControlTest.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Fri, 21 Apr 2017 18:22:03 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/UserControlTest.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/SampleProjects/AlarmButtonDemo.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/AlarmButtonDemo.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Mon, 10 Apr 2017 19:19:05 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/SampleProjects/AlarmButtonDemo.zip/download</guid></item><item><title>Mark Marusich posted a comment on discussion Open Discussion</title><link>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/13c618dd/?limit=25#1280</link><description>I have downloaded the Advanced HMI File (Version 3.5). When trying to open in Visual...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Mark Marusich</dc:creator><pubDate>Mon, 10 Apr 2017 12:45:04 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875090/thread/13c618dd/?limit=25#1280</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch3.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch3.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Sun, 02 Apr 2017 14:33:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch3.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch2.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch2.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Sat, 01 Apr 2017 18:06:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch2.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch1.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch1.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Fri, 31 Mar 2017 14:46:02 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.ControlsV399wPatch1.zip/download</guid></item><item><title>Advanced HMI released /advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399w.zip</title><link>https://sourceforge.nethttps%3A//sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399w.zip/download</link><description/><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Advanced HMI</dc:creator><pubDate>Wed, 15 Mar 2017 16:13:04 -0000</pubDate><guid>https://sourceforge.net/projects/advancedhmi/files/advancedhmi/3.5/Patches/MfgControl.AdvancedHMI.DriversPatch1V399w.zip/download</guid></item><item><title>Nilesh modified a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4/a83e</link><description>Thanku so much Archi. I will make the form hide. and it dosent gives the details...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Nilesh</dc:creator><pubDate>Tue, 14 Mar 2017 10:29:10 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4/a83e</guid></item><item><title>Nilesh posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4/a83e</link><description>ok i will make the form hide. but it dosent gives the details of class and line ...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Nilesh</dc:creator><pubDate>Tue, 14 Mar 2017 10:28:26 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4/a83e</guid></item><item><title>Archie posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4</link><description>It's better to hide the form so it does not have to reload every time. When you get...</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Archie</dc:creator><pubDate>Mon, 13 Mar 2017 11:32:36 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#c7a4</guid></item><item><title>Nilesh posted a comment on discussion Help</title><link>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#fe67</link><description>AdvancedHMIv399t. Visual Studio 2010. I am not hiding the form im closing it.</description><dc:creator xmlns:dc="http://purl.org/dc/elements/1.1/">Nilesh</dc:creator><pubDate>Mon, 13 Mar 2017 04:09:23 -0000</pubDate><guid>https://sourceforge.net/p/advancedhmi/discussion/875091/thread/87f1cc81/?limit=25#fe67</guid></item></channel></rss>