- [Enhancement] Measurement report: Updated Fogra Media Wedge V3
evaluation criteria to ISO 12647-7:2016 version of the standard
(use ΔE*00 and ΔCh for CMY gray).
- [Enhancement] Measurement report: Moved ΔICtCp to general
evaluation criteria so it can be shown in the additional
statistics for all available criteria.
- [Enhancement] Updated simplified chinese translation (thanks to
Mars).
- [Enhancement] Full field pattern insertion: Support the latest
ArgyllCMS 2.0.2 Beta development code.
- [Enhancement] [UI] Consistency: When changing the verification
chart, set the simulate whitepoint relative to display profile
whitepoint option according to the simulation profile (just as
when changing the simuation profile itself) and don't reset the
simulate whitepoint option when changing the simulation
profile.
- [Cosmetic] Automatically fall back to the default verification
chart if the selected one no longer exists (due to the chart
file having been moved or deleted).
- [Cosmetic] Detect highly non-monotonic luminance responses when
creating shaper curves (intended to let creating a profile from
highly non-monotonic measurements fail just as before, but with
a nicer, more descriptive error message instead of the raw
exception from the underlying fitting function).
- [Cosmetic] When creating a profile fails and results in an
error dialog, do not show the superfluous additional “profiling
not finished” message.
- [Minor] Restored the ability to create colorimeter corrections
for virtual displays, which was accidentally removed in
DisplayCAL 3.7.