DisplayCAL 3.8 released

Added in this release:

  • [Feature] SpyderX support (requires ArgyllCMS 2.1.0 or newer,
    use ArgyllCMS 2.1.0_mod to be able to skip instrument self-
    calibration).
  • [Feature] Colorimeter correction information with graph.
  • [Feature] Synthetic ICC profile creator: Drag & drop support
    for TI3 measurement files.
  • [Enhancement] Rudimentary support for hypothetical future
    instruments and their measurement modes (any new instrument
    support added to ArgyllCMS in the future should be fully usable
    in DisplayCAL right away without needing an update for
    instrument-specific measurement modes).
  • [Enhancement] Prefer colorimeter corrections from “ArgyllCMS”
    folder and ignore duplicate (spectral) colorimeter corrections
    from “color” folder (e.g. installed by HCFR under Windows).
  • [Enhancement] Display technology information to aid in the
    choice of a suitable measurement mode or correction.
  • [Enhancement] Default to high-resolution spectrum mode (if
    available) for spectrometers that support it.
  • [Enhancement] Include some additional spectral sample
    colorimeter corrections when importing for i1 Display Pro and
    ColorMunki Display (e.g. MacBook Pro 2016 Retina with PFS
    Phosphor WLED “P3” display, LG OLED 6-series WOLED based on
    samples from LG C6 and E6 OLED TVs, sourced and combined from
    community colorimeter corrections database contributions).

Changed in this release:

  • [UI] Updated simplified chinese localization (thanks to Mars).
  • [UI] Updated french localization (thanks to Jean-Luc Coulon).
  • [Enhancement] Implicitly try to skip repeat instrument self-
    calibration for colorimeters that want it if already done at
    least once per measurement run.
  • [Enhancement] Converted translation file format from JSON to
    YAML for better readability.
  • [Enhancement] Use a localized description for known quality
    spectral sample colorimeter corrections.
  • Use an application-specific download directory for updates and
    supporting files.

Fixed in this release:

  • [Minor] Not all programmed measurement modes were enumerated
    for the K10-A colorimeter (regression of a change in DisplayCAL
    3.7, SVN revision r5557).
  • [Minor] ColorHug/ColorHug2 “auto” measurement mode was not
    working anymore.
  • [Trivial] Curve viewer: Re-introduced being able to view the
    current contents of the video card gamma table if no display
    profile is set or the profile used does not contain
    calibration.
  • [Cosmetic] Curve viewer, profile information: Curve graphing
    identical channel detection was not working properly in some
    cases (only affected synthetic curves).
Posted by Florian Hoech 2019-04-26